Section 4-2. Load classes

Scaffolding shall be classified in the following six classes:
ClassUniformly distributed load kN/m2 (kg/m2)Concentrated load on an area of 500 mm x 500 mm kN (kg)Load of one person on an area of 200 mm x 200 mm kN (kg)Load on partial area
kN/m2 (kg/m2)Partial area m2
10.75 (75)1.50 (150)1.0 (100)Not permitted
21.50 (150)1.50 (150)1.0 (100)Not permitted
32.00 (200)1.50 (150)1.0 (100)Not permitted
43.00 (300)3.00 (300)1.0 (100)5.00 (500)0.4 A
54.50 (450)3.00 (300)1.0 (100)7.50 (750)0.4 A
66.00 (600)3.00 (300)1.0 (100)10.00 (1000)0.5 A

A = area between two pairs of posts.